Manufacturer: Argon Medical Devices, Inc. Category: Arterial Catheters are indicated for use when in instances where continuous invasive blood pressure readings and/or frequent blood gas measurements are required.
Manufacturer: Argon Medical Devices, Inc. Category: Treatment of oncology Proven performance Better quality BioPince needle sequence Maximum length Superior volume
manufacturer: NEXTBIOMEDICAL CO., LTD. Category: Treatment of endovascular embolization Effective embolization by highly cohesiveness and restoring force Anti-contamination vial design No-harmful chemical
manufacturer: NEXTBIOMEDICAL CO., LTD. Category: Treatment of endovascular embolization Resorbable microspheres: Temporary embolization microspheres composed of gelatin Optimal performance: High elasticity and strong cohesion Patented vial design: Vial designed for contamination prevention Tailored to various indications: Resorbable within 24 hours, applicable to various (Nexsphere-H)
Manufacturer: Argon Medical Devices, Inc. Category: Treatment of transjugular liver access in diagnostic and interventional procedures Greater Visibility: Echogenic tips, Alignment marker, Radiopaque band Improved Durability: PEEK material needle/stylet catheters Unparalleled Steerability: Independently steer the curved needle/stylet and the curved stiffening cannula, Directional handles
Manufacturer: Argon Medical Devices, Inc. Category: Percutaneous transjugular liver access during the diagnostic and interventional processes. Flexibility for Tight Turns Tracking for Quality Samples Safety with Every Step
Manufacturer: Argon Medical Devices, Inc. Category: Treatment of transjugular liver access in diagnostic and interventional procedures Greater Visibility: Echogenic tips, Alignment marker, Radiopaque band Improved Durability: PEEK material needle/stylet catheters
manufacturer: ACANDIS Category: Treatment of intracranial aneurysms Over-the-wire system Unique treatment concept Deliverable through the NeuroSpeed® PTA Balloon Catheter with 0.0165” ID PTA and stenting without catheter exchange Minimised procedural risks Suitable for vessels within a diameter range of 2.0 to 4.5 mm * ICAD Intracranial Atherosclerotic Disease
Manufacturer: ACANDIS Category: Treatment of intracranial aneurysms Unique X-ray visibility Perfect vessel wall adaptability Broad range of sizes for tailored treatment options Treatment of vessel diameters from 1.5 - 6.0 mm Up to 3.5 mm device diameter deliverable through 0.021” ID microcatheters True self-expansion Resheathability 3D Sizing Simulation
Manufacturer: ACANDIS Category: Treatment of ischaemic strokes Smallest lasercut stent retriever suitable for vessel diameters down to 1.0 mm Enabling distal thrombectomy Treatment of vessel diameters from 1.0 - 4.0 mm Compatible with 0.0165’’ - 0.021’’ ID microcatheters Outstanding visibility throughout the entire length Effective hybrid-cell design
Manufacturer: ACANDIS Category:Treatment of ischaemic strokes Effective hybrid cell design Outstanding visibility Treatment of vessel diameters from 1.5 - 5.5 mm Compatible with 0.021’’ - 0.027’’ ID microcatehters
Manufacturer: ACANDIS Category: Treatment of intracranial aneurysms Excellent vessel wall apposition and exceptional conformability High visibility Treatment of vessel diameters from 1.5 - 7.0 mm Up to 5.5 mm stent diameter deliverable through 0.0165” ID microcatheters Low thrombogenicity Resheathability up to 90 % of its length * results from In-Vitro Tests
Manufacturer: ACANDIS Category: PTA Balloon Catheter Over-the-wire catheter with an inner diameter of 0.0165" Usable length of 150 cm Various balloon diameters (1.5 / 2.0 /2.5 / 3.0 / 3.5 / 4.0 mm) Balloon working length 8 mm Flexible tip with distal tip X-ray marker ensures atraumatic access to distal stenosis Slim entrance profile and double hydrophilic coating Gentle and…
Manufacturer: ACANDIS Category: Catheter Proximal shaft stiffness for superior pushability Precise navigation and optimised torque control because of 5 transition zones Low friction due to inner PTFE liner Soft, rounded, flexible and preshaped tip (25° multi-purpose) allows easy and atraumatic vessel selection Push-torque-navigate braiding technology for excellent torquability Overall increased kink and ovalisation resistance due to special braiding construction
Manufacturer: ACANDIS Category: Microcatheter Dual layer hydrophilic coating for outstanding lubricity and durability Braiding reinforcement induces superior torquability Shapeable tip for excellent distal navigation Different flexibility zones – best stability at the hub to maximum flexibility at the tip Precise and effective navigation Minimised friction due to inner PTFE liner allows a controlled and safe delivery of therapeutic and diagnostic…
Manufacturer: ASAHI INTECC Category: Micorcatheter and Guide Wire Pre-loaded Microcatheter Radius tip and small profile for distal accessability. Large ID for high volume injection and smooth delivery of embolic materials. Tungsten braiding for lumen integrity and visibility. Pre-shaped tip.
Manufacturer: ASAHI INTECC Category: Microcatheter Tungsten braiding for lumen integrity and visibility. High volume of contrast and therapeutic agents through 0.69mm (0.027 inch) large inner lumen. 0.53mm (0.021 inch) guide wire pre-loaded for ASAHI Masters PARKWAY HF KIT.
Manufacturer: ASAHI INTECC Category: Microcatheter The stable tip supports the guide wire for vessel selectivity Proprietary composite braiding prevents kinking and stretching The 0.64mm ( 0.025inch ) inner diameter at the proximal end assures a high flow rate